Name (Synonyms) | Correlation | |
---|---|---|
D000860 | Hypoxia NIH | 0.21 |
D011014 | Pneumonia NIH | 0.06 |
Name (Synonyms) | Correlation | |
---|---|---|
HP:0012418 | Hypoxemia HPO | 0.21 |
HP:0002090 | Pneumonia HPO | 0.06 |
There is one clinical trial.
The purpose of this study is to evaluate safety, tolerability, and pharmacodynamics of MK-5475 after administration of multiple doses to participants with COVID-19 pneumonia. The primary hypothesis is that MK-5475 when administered to participants with COVID-19 pneumonia and hypoxemia improves arterial oxygenation as measured by the ratio of blood oxygen saturation to fraction of inspired oxygen (SpO2/FiO2 ratio) compared to placebo.
Description: An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of study intervention, whether or not considered related to the study intervention. The number of participants who experience an AE will be reported.
Measure: Number of Participants Who Experience an Adverse Event (AE) Time: Up to ~Day 21Description: An AE is any untoward medical occurrence in a clinical study participant, temporally associated with the use of study intervention, whether or not considered related to the study intervention. The number of participants who discontinued study drug due to an AE will be reported.
Measure: Number of Participants Who Discontinued Study Drug Due to an Adverse Event (AE) Time: Up to ~Day 7Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours post-dose on Day 1 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 1 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 1.
Measure: Change From Baseline to Day 1 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 1 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours on Day 2 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 2 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 2.
Measure: Change From Baseline to Day 2 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 2 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours on Day 3 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 3 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 3.
Measure: Change From Baseline to Day 3 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 3 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours on Day 4 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 4 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 4.
Measure: Change From Baseline to Day 4 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 4 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours on Day 5 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 5 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 5.
Measure: Change From Baseline to Day 5 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 5 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours on Day 6 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 6 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 6.
Measure: Change From Baseline to Day 6 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 6 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)Description: The SpO2/FiO2 ratio is a measure of arterial oxygenation. Noninvasive pulse oximetry will be used to obtain the SpO2/FiO2 ratio. The TWA0-24hrs will be calculated as the area under the curve from 0 to 24 hours on Day 7 divided by the length of time (24 hrs). Baseline is the Day 1 pre-dose measurement and assessments will be conducted pre-dose and at multiple time points post-dose on Day 7 to determine change from baseline in TWA0-24hrs for SpO2/FiO2 on Day 7.
Measure: Change From Baseline to Day 7 in the Time-weighted Average from 0 through 24 hours (TWA0-24hrs) for the Ratio of Blood Oxygen Saturation to the Fraction of Inspired Oxygen (SpO2/FiO2) Time: Baseline, Day 7 (pre-dose and 2, 6, 12, 18, 24 hours post-dose)